Reinsertion of distal biceps ruptures with a single anterior approach: analysis of 14 cases using tension-slide technique and interference screw

Reinsertion of distal biceps ruptures with a single anterior approach: analysis of 14 cases using tension-slide technique and interference screw

Authors

  • Gian Mario Micheloni Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia
  • Luigi Tarallo Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia
  • Giuseppe Porcellini Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia.
  • Michele Novi Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia.
  • Fabio Catani Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia.

Keywords:

distal biceps rupture, single approach, tension-slide technique, interference screw

Abstract

Background: Several techniques of surgical repair of biceps tendon ruptures are described in literature.
Cortical button repair have shown minimal loss of elbow flexion, supination and strength. In this retrospective
study we report the outcomes in terms of elbow function and complications of tension-slide technique and
interference screw. Matherials and methods: 14 patients with complete distal biceps tendon rupture were included in the retrospective study and treated with the same tension-slide technique (BicepsButton® - Arthrex, Inc, Naples, Florida) evaluating the clinical and functional outcomes and the complication rate with a follow-up
average of 18 months. Results: The flexion recovered compare to the healthy contralateral was 96% (min 115° -
max 135°; average 128°), the extension was 97% (min: -2° - max 15°; average 4°), the supination was 90% (min
20° - max 90°; average 75°), the pronation was 95% (min 15° - max 90°; average 76°). The mean Disabilities
of Arm, Shoulder and Hand (DASH) score was 8.1 ± 10.5 and Mayo Elbow Performance Score overall
(MEPS) score was 97.6 ± 8.2. Two patients had LABCN paresthesia, one case, treated 2 months after injury,
had posterior interosseus nerve palsy. One patient had heterotopic ossification at the radiological examination
without consequences for the clinical performances. No case of non-traumatic tendon re-rupture and no case
of ROM deficiency > 20%. In all case the cortical button remains well positioned and no case of osteolysis were
reported. Conclusions: Distal biceps tendon repair with BicepsButton® system seems to be a safe, relyable and
reproducible technique providing excellent clinical, functional and radiological outcomes. Comparing with other
techniques the BicepsButton® system has the advantages of the single approach procedures, the reduction of
surgical time and risk of heterotopic ossifications. (www.actabiomedica.it)

Author Biography

Gian Mario Micheloni, Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia

Corrisponding author:

Micheloni Gian Mario, MD,

Department of Orthopedics and Traumatology, Policlinic of Modena, University of Modena and Reggio Emilia.

E-mail: [email protected]

References

Alech-Tournier F, Elkholti K, Locquet V, Ninou M, Gibert N, Pozzetto M, Breden F et al. Outcomes of distal biceps tendon reattachment using the ToggleLoc™ fixation device with ZipLoop™ technology with single mini-open technique. Eur J Orthop Surg Traumatol 2019;29(4):925-31.

Morrey BF. The elbow and its disorders. Elsevier Health Sciences, New York (2009).

Athwal GS. Management of elbow trauma, an issue of handclinics 31-4, E-Book. Elsevier Health Sciences, New York (2016).

Morrey BF, Askew LJ, An KN, Dobyns JH. Rupture of the distal tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 1985;67(3):418-21.

Baker BE, Bierwagen D. Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Joint Surg Am 1985;67(3):414-7.

Agins HJ, Chess JL, Hoekstra DV, Teitge RA. Rupture of the distal insertion of the biceps brachii tendon. Clin Orthop Relat Res 1988 Sep;234:34-8.

Bell RH, Wiley WB, Noble JS, Kuczynski DJ. Repair of distal biceps brachii tendon ruptures. J Shoulder Elbow Surg 2000;9(3):223-6.

Boyd HB, Anderson LD. A method for reinsertion of the distal biceps brachii tendon. J Bone Joint Surg Am 1961;43(7):1041-3.

Barnes SJ, Coleman SG, Gilpin D. Repair of avulsed insertion of biceps. A new technique in four cases. J Bone Joint Surg Br 1993;75(6):938-9.

Lintner S, Fischer T. Repair of the distal biceps tendon using suture anchors and an anterior approach. Clin Orthop Relat Res 1996;322:116-9.

Sotereanos DG, Pierce TD, Varitimidis SE. A simplified method for repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 2000;9(3):227-33.

Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D. Repair of distal biceps tendon rupture: a new technique using the Endobutton. J Shoulder Elbow Surg 2000;9(2):120-6.

Watson JN, Moretti VM, Schwindel L, Hutchinson MR. Repair techniques foracute distal biceps tendon ruptures: a systematic review. J Bone Joint Surg Am 2014;96(24):2086-90.

Huynh T, Leiter J, MacDonald PB, Dubberley J, Stranges G, Old J, Marsh J. Outcomes and Complications After Repair of Complete Distal Biceps Tendon Rupture with the Cortical Button Technique. JBJS Open Access 2019;4(3). pii: e0013.1-6.

Bellringer SF, Phadnis J, Human T, Redmond CL, Bain GI. Biomechanical comparison of transosseus cortical button and footprint repair techniques for acute distal biceps tendon ruptures. Shouder Elbow 2020;12(1)54-62.

Porcellini G, Rotini R, Stignani Kantar S, Di Giacomo S. The elbow: principles of surgical treatment and rehabilitation. Springer 2018.

Tarallo L, Lombardi M, Zambianchi F, Giorgini A, Catani F. Distal biceps tendon rupture: advantages and drawbacks of the anatomical reinsertion with a modified double incision approach. BMC Musculoskelet Disord 2018;19(1):364.

Balabaud L, Ruiz C, Nonnenmacher J, Seynaeve P, Kehr P, Rapp E. Repair of distal biceps tendon ruptures using a suture anchor and an anterior approach. Hand Surg Br 2004;29(2):178–82.

Citak M, Backhaus M, Seybold D, Suero EM, Schildhauer TA, Roetman B. Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques. Knee Surg Sports Traumatol Arthrosc 2011;19(11):1936–41.

Gupta RK, Bither N, Singh H, Kapoor S, Chhabra A, Garg S. Repair of the torn distal biceps tendon by endobutton fixation. Indian J Orthop 2012;46(1):71–6.

Tarallo L, Zambianchi F, Mugnai R, Costanzini CA, Catani F. Distal biceps tendon rupture reconstruction using muscle-splitting double-incision approach. World J Clin Cases. 2014;2(8):357–61.

Christopher L Camp MD, et al. Single-incision technique for repair of distal biceps tendon avulsions with intramedullary cortical button. Arthroscopy Techniques. 2016;5(2):303–7.

Grewal R, Athwal GS, MacDermid JC, Faber KJ, Drosdowech DS, El-Hawary R, King GJ. Single versus double-incision technique for the repair of acute distal biceps tendon ruptures: a randomized clinical trial. J Bone Joint Surg Am 2012;94(13):1166–74.

Greenberg JA, Fernandez JJ, Wang T, Turner C. EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 2003;12:484–490.

DiRaimo MJ, Maney MD, Deitch JR. Distal biceps tendon repair using the toggle loc with zip loop. Orthopedics 2008;31:1201–1203.

Kodde IF, Bekerom MPJ van den, Eygendaal DE. Reconstruction of distal biceps tendon ruptures with a cortical button. Knee Surg Sports Traumatol Arthrosc 2013;23(3):919–925.

Lo EY, Li C-S, Van den Bogaerde JM. The effect of drill trajectory on proximity to the posterior interosseous nerve during cortical button distal biceps repair. Arthroscopy 2011;27:1048–1054.

Potapov A, Laflamme YG, Gagnon S, Canet F, Rouleau DM. Progressive osteolysis of the radius after distal biceps tendon repair with the bioabsorbable screw. J Shoulder Elbow Surg 2011;20: 819-826.

Matthews EC, Brinsden MD, Murphy AJ, Guyver PM. The biotenodesis screw and endobutton technique for repair for acute distal biceps tendon rupture. Clin Arch Bone Joint Dis 2018;1:006.

Watson JN, Moretti VM, Schwindel L, Hutchinson MR. Repair techniques for acute distal biceps tendon ruptures: a systematic review. J Bone Joint Surg Am 2014; 96A(24):2086–90.

Amin NH, Volpi A, Sean Lynch T, Patel RM, Cerynik DL, Schickendantz MS, Jones MH. Complications of distal biceps tendon repair: A Meta-analysis of single-incision versus double-incision surgical technique. Orthop J Sports Med 2016;4(10):2325967116668137.

Spang JT, Weinhold PS, Karas SG. A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries. J Shoulder Elbow Surg 2006;15:509–514.

Chavan PR, Duquin TR, Bisson LJ. Repair of the ruptured distal biceps tendon: a systematic review. Am J Sports Med 2008;36:1618–1624.

Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adams DA, Arciero RA. Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 2007;35:252–258.

Downloads

Published

30-05-2020

How to Cite

1.
Reinsertion of distal biceps ruptures with a single anterior approach: analysis of 14 cases using tension-slide technique and interference screw. Acta Biomed [Internet]. 2020 May 30 [cited 2024 Apr. 19];91(4-S):183-8. Available from: https://www.mattioli1885journals.com/index.php/actabiomedica/article/view/9551

Most read articles by the same author(s)

1 2 3 > >>