Dynamic left ventricular outflow tract obstruction induced by intra-aortic balloon pump in patient with angioedema
Abstract
Background: Intra-aortic balloon pump is used for temporary mechanical support of failing left ventricle. It works by reducing the arterial afterload during ventricular systole to reduce myocardial work and increasing diastolic proximal aortic pressure to improve coronary perfusion. Rarely, intra-aortic balloon pump (IABP) can become the cause of severe haemodynamic compromise, causing dynamic left ventricular outflow tract obstruction.
Case presentation: An 88-yo man presented with angiotensin converting enzyme inhibitor (ACEI) - induced angioedema. He received steroids and adrenaline, but progressed to the respiratory arrest, requiring emergency awake fiberoptic intubation and mechanical ventilation. Echocardiography revealed catecholamine-induced reversed Takotsubo cardiomyopathy. The patient suffered asystolic cardiac arrest on arrival to intensive care unit (ICU), requiring cardiopulmonary resuscitation (CPR). Bradycardia and hypotension were treated with atrial pacing and (IABP). Icatibant was administered for angioedema. After several hours of haemodynamic stability, severe hypotension returned. Bedside echocardiographic diagnosis of recovery from Takotsubo and new development of IABP-induced dynamic left ventricular outflow tract obstruction (DLVOTO) was made. Stopping IABP resulted in rapid haemodynamic recovery. Repeated doses of Icatibant were needed. The patient survived and returned to independent living.
Conclusions: Immediate echocardiographic recognition of iatrogenic DLVOTO caused by IABP allows discontinuation of IABP support as a life-saving intervention. Dynamic application of spectral Doppler with changes in IABP settings is required for correct diagnosis.
References
1. Guyer A, Banerji A 2023 ACE inhibitor-induced angioedema. In UpToDate 10 March 2023
2. Stone C, Brown NJ (2017) Angiotensin-converting Enzyme Inhibitor and Other Drug-associated Angioedema. Immunol Allergy Clin North Am 37(3):483–495
3. Brown T, Gonzalez J, Monteleone C (2017) Angiotensin-converting enzyme inhibitor-induced angioedema: A review of the literature. J Clin Hypertens (Greenwich) 19(12):1377–1382
4. Sinert R, Levy P, Bernstein JA, Body R et al (2017) Randomized Trial of Icatibant for Angiotensin-Converting Enzyme Inhibitor-Induced Upper Airway Angioedema. J Allergy Clin Immunology: Pract 5(5):1402–1409e3. https://doi.org/10.1016/j.jaip.2017.03.003
5. Yang JH, Park SW, Yang JH et al (2008) Dynamic left ventricular outflow tract obstruction without basal septal hypertrophy, caused by catecholamine therapy and volume depletion. Korean J Intern Med 23:106–109
6. Awad HH, McNeal AR, Goyal H (2018) Reverse Takotsubo cardiomyopathy: a comprehensive review. Ann Transl Med 6(23):460. https://doi.org/10.21037/atm.2018.11.08
7. Figaro R, Thornton I, Scott JP, Sluhoski J (2024) Anesthetic management of Intra-aortic. Balloon Pump-Induced Systolic Anterior Motion of the Mitral Valve During Coronary Artery Bypass Grafting. Cureus 16(3):e56815. https://doi.org/10.7759/cureus.56815
8. Coddens J, Van Alphen J, Deloof Th, Hendrickx J (2002) Dynamic left ventricular outflow tract obstruction caused by afterload reduction induced by intra-aortic balloon counterpulsation. J Cardiothorac Vasc Anesth 16(6):P749–751
9. Cohen R, Rivagorda J, Elhadad S (2006) Asymmetric septal hypertrophy complicated by dynamic left ventricular obstruction after intra-aortic balloon counterpulsation placement in the setting of anterior myocardial infarction. J Invasive Cardiol 18(7):E207–E208
10. Takamura T, Dohi K, Satomi A et al (2012) Intra-aortic balloon pump induced left ventricular outflow tract obstruction and cardiogenic shock after very late stent thrombosis in the left anterior descending coronary artery. J Cardiol Cases 6:e137–140
11. Wong SW, Ng KXJ (2021) Intra-aortic Balloon Pump Induced Left Ventricular Outflow Tract Obstruction and cardiogenic Shock: A Case Report. Int J Crit Care Emerg Med 7:123. https://doi.org/10.23937/2474-3674/1510123
12. Griffin M, Odanovic N, McNamara R et al (2023) Intra-Aortic Balloon Pump Exacerbates Left Ventricular Outflow Tract Obstruction in a Patient with Takotsubo and Hypertrophic Cardiomyopathy. CASE (JASE) 7(12):502–507
13. Nan Tie E, Dinh D, Chan W et al (2023) Melbourne Interventional Group Investigators. Trends in Intra-Aortic Balloon Pump Use in Cardiogenic Shock After the SHOCK-II Trial. Am J Cardiol 191:125–132. https://doi.org/10.1016/j.amjcard.2022.12.019
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Konstantin Yastrebov, Gregory Cranney (Author)

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Transfer of Copyright and Permission to Reproduce Parts of Published Papers.
Authors retain the copyright for their published work. No formal permission will be required to reproduce parts (tables or illustrations) of published papers, provided the source is quoted appropriately and reproduction has no commercial intent. Reproductions with commercial intent will require written permission and payment of royalties.