Sonographic nystagmus: a case report of lateral semicircular canal benign paroxysmal positional vertigo
Keywords:
Ocular ultrasonography, Ophthalmic ultrasound, Nystagmus, Benign paroxysmal positional vertigo, Vertigo, Emergency medicine, Frenzel gogglesAbstract
Background: Nystagmus, a critical diagnostic sign of vertigo and dizziness, reflects disturbances in the vestibular system. The accurate characterisation of nystagmus aids in distinguishing between peripheral and central causes, such as benign paroxysmal positional vertigo (BPPV) and stroke, respectively. Traditional methods for assessing nystagmus involve visual inspection or the use of Frenzel goggles. However, in cases where patients are unable to keep their eyes open owing to severe vertigo, such an evaluation becomes challenging. To date, sonographic imaging has not been used as a diagnostic method for nystagmus. We present a case in which ocular ultrasonography was used to assess nystagmus and aid in the diagnosis of BPPV.
Case presentation: A 56-year-old woman presented with recurrent vertigo exacerbated by positional changes. Clinical examination revealed no spontaneous nystagmus or neurological deficits. Because the patient was unable to keep her eyes open during positional testing, ocular ultrasonography was performed using a 9-MHz linear transducer. Imaging revealed direction-changing horizontal nystagmus, consistent with the apogeotropic variant of lateral semicircular canal BPPV. The diagnosis was subsequently confirmed by an otolaryngologist using Frenzel goggles. The patient was conservatively managed.
Conclusions: This is the first report on the use of ocular ultrasonography to assess nystagmus. Despite certain limitations, this technique may be a valuable supplementary tool, particularly in settings in which conventional examinations are hindered or unavailable. Ophthalmic sonography has the potential to enhance vestibular assessments in emergency and outpatient settings.
References
1. Kerber KA, Morgenstern LB, Meurer WJ, McLaughlin T, Hall PA, Forman J, Fendrick AM, Newman-Toker DE (2011) Nystagmus assessments documented by emergency physicians in acute Dizziness presentations: A target for decision support? Acad Emerg Med 18:619–626
2. Kerber KA, Newman-Toker DE (2015) Misdiagnosing dizzy patients: Common pitfalls in clinical practice. Neurol Clin 33:565–575, viii
3. Tarnutzer AA, Straumann D (2018) Nystagmus. Curr Opin Neurol 31:74–80
4. Cnyrim CD, Newman-Toker D, Karch C, Brandt T, Strupp M (2008) Bedside differentiation of vestibular neuritis from central vestibular pseudoneuritis. J Neurol Neurosurg Psychiatry 79:458–460
5. Cole SR, Honaker JA (2022) Benign paroxysmal positional vertigo: effective diagnosis and treatment. Cleve Clin J Med 89:653–662
6. Parnes LS, Agrawal SK, Atlas J (2003) Diagnosis and management of benign paroxysmal positional vertigo (BPPV). CMAJ 169:681–693
7. Zuma E, Maia F, Ramos BF, Cal R, Brock CM, Mangabeira Albernaz PL, Strupp M (2020) Management of lateral semicircular Canal benign paroxysmal positional vertigo. Front Neurol 11:1040
8. Power L, Murray K, Szmulewicz DJ (2020) Characteristics of assessment and treatment in benign paroxysmal positional vertigo (BPPV). J Vestib Res 30:55–62
9. De Bernardo M, Vitiello L, De Pascale I, Capasso L, Cornetta P, Rosa N (2022) Optic nerve ultrasound evaluation in idiopathic intracranial hypertension. Front Med (Lausanne) 9:845554
10. Kishk NA, Ebraheim AM, Ashour AS, Badr NM, Eshra MA (2018) Optic nerve sonographic examination to predict Raised intracranial pressure in idiopathic intracranial hypertension: the cut-off points. Neuroradiol J 31:490–495
11. Lahham S, Shniter I, Thompson M, Le D, Chadha T, Mailhot T, Kang TL, Chiem A, Tseeng S, Fox JC (2019) Point-of-care ultrasonography in the diagnosis of retinal detachment, vitreous hemorrhage, and vitreous detachment in the emergency department. JAMA Netw Open 2:e192162
12. Kaushik S, Ichhpujani P, Ramasubramanian A, Pandav SS (2008) Occult intraocular foreign body: ultrasound biomicroscopy holds the key. Int Ophthalmol 28:71–73
13. Wang K, Liu J, Chen M (2015) Role of B-scan ultrasonography in the localization of intraocular foreign bodies in the anterior segment: A report of three cases. BMC Ophthalmol 15:102
14. Karki BV, Shrestha N, Neupane A, Kc H, Shrestha PS, Acharya S (2023) Use of bedside ultrasound for ophthalmic evaluation in a case of traumatic brain injury: A case report. Nepal J Ophthalmol 15:105–109
15. Wijdicks EF, Sheth KN, Carter BS, Greer DM, Kasner SE, Kimberly WT, Schwab S, Smith EE, Tamargo RJ, Max Wintermark M, on behalf of the American Heart Association Stroke (2014) Recommendations for the management of cerebral and cerebellar infarction with swelling: a statement for healthcare professionals from the American heart association/American stroke association. Stroke 45:1222–1238
16. Miller DL, Abo A, Abramowicz JS, Bigelow TA, Dalecki D, Dickman E, Donlon J, Harris G, Nomura J (2020) Diagnostic ultrasound safety review for point-of-care ultrasound practitioners. J Ultrasound Med 39:1069–1084
17. U.S. Food and Drug Administration (FDA), Center for Devices and Radiological Health (2023) Marketing Clearance of Diagnostic Ultrasound Systems and Transducers: Guidance for Industry and Food and Drug Administration Staff. FDA, Silver Spring, MD
18. Gurthie J (2021) Ophthalmic sonography: through the lens of a sonographer. J Diagn Med Sonogr 37:517–520
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Yuki Munekata, Chisato Matsumoto, Kento Sakoda, Yuki Takahashi (Author)

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Transfer of Copyright and Permission to Reproduce Parts of Published Papers.
Authors retain the copyright for their published work. No formal permission will be required to reproduce parts (tables or illustrations) of published papers, provided the source is quoted appropriately and reproduction has no commercial intent. Reproductions with commercial intent will require written permission and payment of royalties.